PC vs UPC vs APC Connector: Selecting the Right Fiber Connector Type

Updated on Fri Aug 08 2025

Fiber optic connectors play a critical role in ensuring reliable and efficient data transmission in fiber optic networks. When choosing a fiber connector, it's essential to consider factors such as insertion loss, return loss, and compatibility with the network equipment. Three common types of fiber connectors are PC (Physical Contact), UPC (Ultra Physical Contact), and APC (Angled Physical Contact). In this article, we will compare PC, UPC, and APC connectors, discussing their features, advantages, and applications to help you select the right fiber connector type for your specific requirements.


PC (Physical Contact) Connector:

1.1 Features:

PC connectors have a flat end face that comes into direct physical contact with the mating connector. The end faces are polished to a slight curvature to minimize the air gap between the connectors, reducing insertion loss and back reflection.

1.2 Advantages:


Low insertion loss: PC connectors offer low insertion loss, making them suitable for most standard fiber optic applications.

Ease of use: PC connectors are easy to install and widely available in the market.

Cost-effective: PC connectors are generally more cost-effective compared to UPC and APC connectors.

1.3 Applications:

PC connectors are commonly used in telecommunications networks, LAN (Local Area Network) applications, and data center cabling. They are suitable for single-mode and multimode fibers where moderate return loss requirements are acceptable.


UPC (Ultra Physical Contact) Connector:

2.1 Features:

UPC connectors have a slight spherical end face that provides better physical contact between the mating connectors compared to PC connectors. The spherical shape ensures a larger contact area, reducing insertion loss and back reflection.

2.2 Advantages:


Low insertion loss: UPC connectors offer even lower insertion loss compared to PC connectors due to their improved end face geometry.

High return loss: UPC connectors provide high return loss, minimizing back reflection and ensuring better signal quality.

High durability: UPC connectors have high durability and can withstand multiple insertion and removal cycles without significant performance degradation.

2.3 Applications:

UPC connectors are commonly used in high-speed data transmission applications, fiber-to-the-home (FTTH) installations, and CATV (Cable Television) networks. They are suitable for both single-mode and multimode fibers and provide better performance compared to PC connectors.


APC (Angled Physical Contact) Connector:

3.1 Features:

APC connectors have an angled end face with an 8-degree angle. The angled design minimizes back reflection by redirecting reflected light away from the source. APC connectors provide the highest return loss performance among the three connector types.

3.2 Advantages:

fiber connector

Low insertion loss: APC connectors offer low insertion loss similar to PC and UPC connectors.

Excellent return loss: APC connectors provide the highest return loss performance, making them ideal for applications that require minimal back reflection.

High signal quality: APC connectors reduce the effects of back reflection, ensuring high-quality signal transmission.

3.3 Applications:

APC connectors are commonly used in applications that demand high precision and minimal back reflection, such as fiber optic systems with high-speed data transmission, telecommunications networks, and FTTx (Fiber to the x) deployments.


Selecting the Right Fiber Connector Type:

When selecting the appropriate fiber connector type, consider the following factors:

Network requirements: Determine the required insertion loss, return loss, and compatibility with network equipment.

Application-specific needs: Consider the application's data rate, distance, and environmental conditions.

Cost considerations: Evaluate the budget and cost-effectiveness of the connector type.

For most standard applications, PC connectors provide a cost-effective solution with satisfactory performance. UPC connectors are suitable for applications that require better signal quality and are commonly used in high-speed data transmission scenarios. APC connectors are ideal for applications that demand minimal back reflection and high precision.


Conclusion:

Selecting the right fiber connector type is crucial for ensuring reliable and efficient data transmission in fiber optic networks. PC, UPC, and APC connectors offer varying performance levels in terms of insertion loss, return loss, and back reflection. PC connectors are commonly used in standard applications, UPC connectors provide better signal quality, and APC connectors offer the highest return loss performance. Consider the specific requirements of your network and application to choose the most suitable connector type that meets your performance needs and budget constraints.